Note: 50mm deep is the preferred dimension for the installation of any horizontal bedding joints referred to in the above examples.

 

A

• Drill M12 hole through brick/masonry and then 150mm into sound end grain timber.
• Air flush.
• Inject Rotafix Structural Adhesive into the drilled hole using the Rotafix extension tube.
• Install Rotaflex pultruded 8mm diameter rod, to finish 10mm below external brick masonry.
• Flush point.

B

• Drill M12 hole through masonry.
• Wood auger (M12) through first and second joist.
• Remove floorboard, air flush hole in masonry.
• Install 8mm threaded ss Rotaflex rod
• Fix nut and washer.
• Backfill masonry hole with Rotafix Structural Adhesive

C

• Remove floorboard, drill at 45o through joists at 120mm into masonry/brick.
• Air flush.
• Inject Rotafix Structural Adhesive.
• Install 8mm diameter threaded ss Rotaflex rod.
• Allow to cure.
• Tension nut and washer.

 

FOR FURTHER INFORMATION CONSULT THE FOLLOWING ROTAFIX DATA SHEETS

CB10T (PD3550/4) TC4 (PD3475/10) CEMBOND (PD3160-1/2)
Rotafix Structural Adhesive (PD3560/1) ROTAFLEX ROD (PD3664-3711/11) SPIROTIE (PD3801-2/1)

DEVELOPERS, MANUFACTURERS AND SUPPLIERS OF RESIN AND POLYMER PRODUCTS
"Advice and assistance provided without charge is given in good faith but without responsibility". Recommendations regarding the methods, use of materials and construction details are given as a service to designers, contractors and end users. Any drawings are intended only to illustrate various possible applications and should NOT be taken as the basis of design.